I. Introduction

The ZNJL2005-I intelligent swabbing instrument is our company's newly developed automatic swabbing recording instrument. It is suitable for swabbing operations such as well stimulation and liquid discharge in oil wells with low formation pressure. It can automatically record the depth of wireline run-in, time, and number of swabbing operations during swabbing. It can display current data and the number of swabbing operations for the current shift, and can print swabbing operation information for the current or any past time period. The ZNJL2005-I intelligent swabbing instrument is the latest researched and developed product. The instrument has a high degree of intelligence and high measurement accuracy, and adopts modern advanced microprocessor technology, enabling complex calculations and processing and greatly improving system performance, functions, and reliability. The instrument also has powerful Flash storage capacity, allowing large amounts of data to be accumulated and saved anytime and anywhere.

ZNJL2005-I Intelligent Swabbing Instrument Maximum measuring depth 9999 m, swabbing count 999 times, data storage not less than records, working power DC V, ambient temperature It has good shock resistance, explosion-proof, waterproof, and corrosion resistance performance. The instrument uses only highly reliable components and adopts anti-interference and reinforced structural design, enabling continuous operation in harsh environments. The instrument is simple to install and easy to operate, and can be used with various swabbing wellhead pulleys (crown pulley or traveling pulley) . A dedicated data setter is provided for convenient modification and adjustment of parameters, preventing unintended operation by unauthorized personnel.

II. Main Performance Specifications

Maximum measuring depth: 9999 m Maximum displayed swabbing count: 999 times Data storage capacity: not less than 30000 records, Working power: DC 24V Power consumption: not more than 4.5W Working ambient temperature: -20 to +80 Main unit weight: 1.5kg Main unit dimensions: 210 ( width height depth ) mm

III. Installation and Commissioning

The main unit should be placed in an environment free from rain and snow and strong direct sunlight, and can be placed in any position. For ease of operation and data observation, it is usually placed on a horizontal surface. On surfaces with strong vibration, a shock-absorbing pad should be placed under the instrument and secured with elastic straps. Instrument front panel Instrument rear panel Power connection This instrument uses a 12-24V DC power supply. If powered by a locomotive battery, the power cable must be reliably connected to the battery; the other end of the power cable can be directly connected to the power terminal on the rear panel of the instrument. The power terminals of this unit can be connected without regard to polarity.

To connect the power conveniently and safely, a pre-prepared power cable (called a power lead) can be used to connect to the power terminal socket on the rear panel of the instrument; the other end has an open-type plug and is connected via a long insulated conductor with a socket to the DC power supply (such as the locomotive battery terminal). In this way, during maintenance or temporary shutdown, the two-core plug can be unplugged without disconnecting the wiring at the locomotive battery end, avoiding short-circuit accidents caused by careless operation. If using locomotive DC power, it is recommended to use 24V

supply rather than or other unstable power sources, to ensure reliable and stable operation of the unit. In indoor locations with AC power, the supplied main unit power adapter can be used for power supply. The main unit power adapter is suitable for AC 220V 20%/50Hz range. Sensor installation The sensor consists of a probe and a cylindrical magnet; when the probe approaches the magnet, a signal can be detected. The magnet is installed on the side profile of the outer ring of the rotating wheel of the swabbing wellhead pulley (crown pulley or traveling pulley), while the sensor probe is installed on the steel plate of the

pul ley support bracket. Usually it is more convenient to install the magnet and sensor on the traveling pulley, but the sensor is susceptible to oil contamination and collision. Sensor probe installation The sensor probe bracket should be fixed on one side of the pulley support bracket steel plate, with the installation direction as shown in the right figure, and its relative position should be below the wireline groove of the pulley. To fix the sensor probe bracket, holes need to be drilled in the pulley support bracket steel plate. According to the dimensions of the sensor bracket, drill one Φ

13mm hole and four M5 screw holes in the pulley support bracket steel plate. The diameter mm hole is used to pass the probe, and the four diameter mm screws are used to fix the sensor probe. The holes for the diameter mm screws can be tapped holes or through holes. Note that spring washers should be installed on the fixing screws, and the screw shanks extending out of the traveling pulley support bracket steel plate must not be higher than the sensor probe. For accurate drilling, the sensor bracket drilling template provided with the instrument (usually in the document bag) can be used. Cut out a graphic outline from the drawing, align the position, paste the graphic onto the support bracket on the side of the pulley, and drill at the marked circles drawn on the paper.

Magnet installation First measure the position of the magnet relative to the sensor probe, that is, keep the center of the circular magnet vertically aligned with the center of the sensor probe face, and make a mark. Drill a recess of diameter 20mm (slightly larger) and depth 1mm at the corresponding position on the side profile of the pulley; drill and tap the center (use an M5mm countersunk screw, with length determined by the wall thickness of the pulley outer ring profile, usually M5 10mm ); clean off oil contamination, apply modified acrylic adhesive, bond the face of the magnet with the flat hole at the center onto the pulley, and tighten with an M5mm

countersunk screw, so that the circular magnet is firmly fixed on the outer ring side profile of the pulley. The side of the magnet with the countersunk hole at the center faces outward, that is, toward the sensor probe. Note: The magnet is made of high-tech and rare earth materials and has extremely strong magnetism. Do not place it arbitrarily; keep it away from magnetic cards, watches, mobile phones, etc. During installation, hold the magnet firmly with your fingers to prevent it from being attracted and detached by surrounding iron parts. Once it is attracted into the recess, it is very difficult to remove; sometimes violent attraction to other metal or dropping onto a hard surface may shatter the magnet. Therefore, first confirm the intended placement position and the orientation of the magnet before placing it.

Installation essentials Ensure that when the pulley rotates to the position with the magnet, the circular magnet can align with the sensor probe, and the vertical spacing between the center of the circular magnet and the center of the sensor probe is within 5-10mm. Shims can be added under the sensor probe bracket to adjust the spacing between the probe and the magnet. A section of cable on the sensor itself is called the "sensor lead" (length approximately m or more). One end of the "lead" is directly soldered to the signal transmission cable (not greater than m). To avoid rain, snow, and oil contamination, the cable joint should be wrapped with high-strength protective tubing and waterproof tape. If necessary, this section of cable can be supported with a bracket to prevent long-term immersion in water or oil. The "lead" should have some slack to prevent damage from strong vibration during pulley operation.

The plug connected to the other end of the signal transmission cable can be connected to the corresponding probe socket on the instrument. Sensor commissioning Turn on the instrument power, and check whether the sensor is correctly installed through the two indicator lights marked A at the lower left of the instrument panel. When the pulley is rotated and the magnet is perpendicular to the sensor probe, the or indicator on the panel lights up. Ensure that when the magnet is perpendicular to the sensor probe, the indicator lights; when the magnet is perpendicular to the sensor probe, the indicator lights; when the magnet is between perpendicular to the

probe and the probe, both indicators light simultaneously. Adjust the A direction of the sensor probe (the direction selector switch on the rear panel of the instrument) to ensure that when the pulley is rotated so that the wireline moves in the downward direction, the indicators appear in sequence A on → A and B on simultaneously → B on ; this confirms that the wireline downward counting is positive (+ After reliable installation and commissioning, check and tighten the screws of the sensor and its bracket and the connecting cables, and if necessary, pot with waterproof adhesive. The cable must not be pulled forcefully, and must be protected from heavy objects and sharp tools. When the cable is coiled for storage, it must be wound on the cable reel, and the sensor and plug must be wrapped with protective tape to prevent moisture and dust ingress.

Parameter query and setting This instrument uses a dedicated setter to set various parameters on the main unit, and the previously set parameters can be modified and queried at any time. The set parameters can be retained in the main unit for a long time. Without the setter, parameters on the main unit cannot be modified or queried, which prevents unintended operation by unauthorized personnel. Before setting or querying parameters, first turn off the main unit power, insert the setter connector plug into the corresponding socket on the rear panel of the main unit, and then turn on the main unit power. Press the

[Query] key to sequentially check whether the date, time, circumference, and local well number are correct. If incorrect, the parameters need to be reset. The specific steps are as follows: (1) Date and time setting Press the [Time] key; the "Time" indicator in the bar frame on the panel lights up, and the digital display shows the current date. Press the [Up], [Down], [Left], and [Right] keys to set the date. Then press the [Time] key again, and the digital display will show the current time. Press the [Up], [Down], [Left], and [Right] keys to calibrate the time. If an input error occurs, press the [Cancel] key and then repeat the operation.

After completion, press the [Enter] key to save the set date and time values; press the [Cancel] key to cancel this setting. The time has been calibrated before the instrument leaves the factory, so users usually do not need to operate it again. Note: The year is two digits, for example, 14 means year; month is two digits, for example 03 means month; day is two digits, for example 05 means day; time is in 24 -hour format, and can be set to hour and minute. (2) Pulley circumference setting The pulley circumference should be measured from the centerline of the wireline cross-section, in units of mm (millimeters)

There are many methods for measuring the circumference, which can be selected according to actual conditions. The more accurate the circumference measurement, the higher the numerical accuracy of the instrument's length measurement. After measuring the circumference, press the [Circumference] key, then press the [Up], [Down], [Left], and [Right] keys to enter the measured circumference value (in millimeters). If the input is correct, press the [Enter] key to save the current circumference value. If the input is incorrect, press the [Cancel] key and then repeat the operation.

Special note:

After setting the circumference, the power must be turned off and on again for it to take effect. (3) Well number setting The well number consists of code a, code and code Press the [Well No.] key; the "Well No." indicator in the bar frame on the main unit panel lights up. At this time, the length display and the count display show "code , code and code ". Press the [Up], [Down], [Left], and [Right] keys to set the well number. After completion, press the [Enter] key to save the current values. If the input is incorrect, press the [Cancel] key and then repeat the operation. After all setting operations are completed, turn off the main unit power, remove the setter, and then turn the main unit power back on to enter the correct working state.

The representation relationship of the local well number is shown in Appendix 1 and Appendix 2. Formatting (FMT + Enter) When the instrument has been used for a long time and the previous measurement data in the instrument no longer needs to be retained, a formatting (initialization) operation can be performed, which frees up a large amount of storage space for saving new measurement data. Formatting is also called initialization. This instrument requires the setter to perform the formatting operation. When deciding to format the unit, connect the setter to the main unit, turn on the power, and on the setter

press the [FMT] and [Enter] keys simultaneously At this time, intermittent "beep" sounds from the main unit can be heard, and the "Clear" indicator on the display panel lights up, indicating that the formatting process has started. After formatting is complete, the "beep" sounds stop immediately and the "Clear" indicator goes out. In this way, the instrument will record data anew when used again. Suggestion: The setter should be operated and kept by designated personnel.

V. Operating Method

Power-on and working state After the instrument is turned on, the length display shows "0" and the count shows " ". When the traveling pulley rotates, that is, when the swab goes down, the left display shows the current length measurement value (unit: meter). Note that, starting from the "0" point at the wellhead, the downward direction of the swab is positive (+); this is determined by the sensor installation direction (see the sensor connection instructions). The right display shows the current measurement count (unit: times), which is also the number of times the "swab" has run down to the working point and then been pulled back to the wellhead. Pressing the

[Clear 2] key will restart counting from " "; this is only a reminder for the personnel on the current shift and is not included as recorded data, while the actual recorded count is accumulated in chronological order. When the swab has run down and is then pulled back near the wellhead, a whistle can be heard, indicating that the swab has run down to the working point and returned to the starting point (wellhead) for one operation cycle. The whistle also indicates that the measurement values before this have been recorded. Note that data is recorded only when each "swab" has run down m (greater than

m is effective) and then been pulled back to the wellhead (± m). When the swab is pulled up to the wellhead and then run down again from the wellhead (within 50 meters of the wellhead), the displayed data automatically resets to zero. Sometimes, due to pulley slipping and other reasons, the number displayed upon returning to the starting point is not " "; this is an error and can usually be ignored. If this numerical error is considered large, you can press [Clear 1] when the swab is about to run down again, so that the starting display is " Note: During and after the swab run-down process, do not press the [Clear 1] key; otherwise, the current record will not match the actual operation.

This unit is designed with the downward direction as "positive ( )". When a " " sign appears in front of the display, it indicates that the position has returned beyond the starting " " point, and length measurement may then start from the opposite direction. This situation is an error caused by various reasons, such as slipping between the pulley and wireline during operation. Printing data This unit is equipped with a desktop 40 -character high-speed serial micro printer. Please read the printer's instruction manual before use. When preparing to print data, first turn off the main unit power, connect the

setter to the main unit; insert the printer data cable plug into the corresponding printer socket on the main unit panel, and then turn on the main unit power and the printer power. Press the [Select] key on the setter; the digital display will show the start date for printing and the number of consecutive days to print. Press the [Up], [Down], [Left], and [Right] keys to select the start date and number of days; each time, 1-29 days from the selected date can be selected. For example, if month day is selected and the number of days is selected as then the data from month day to month day can be printed.

Press the [Right] key repeatedly, and the " " indicators in the bar frame on the panel will light up in sequence. When the " " indicator is selected and lit, it indicates printing " " data; when the " " indicator is selected and lit, it indicates printing " " data; when the " " indicator is selected and lit, it indicates printing " " data. If no number of days is selected and the " " indicators are all off, it indicates printing all data for the current day. If an input error occurs, press the [Cancel] key and then repeat the operation. Press the [Enter] key to start printing. During printing, you can press the [Cancel] key and use the printer's operation keys (see the printer manual for details) to exit the printing state.

After pressing the [Select] key, you can press the [Enter] key at any time to print data according to the currently set parameters. For example, press the [Select] key and then press the [Enter] key to start printing all data for the current day. For other printer operations and precautions, please refer to the printer's instruction manual.

Note:

The printer power supply should be used in accordance with the requirements of the printer manual. Do not use other power adapters; otherwise, the printer may be damaged.

VI. Precautions

1. Please read the manual carefully before installing and using this unit.

When the DC power supply voltage is extremely unstable, for example, when the unit is working in a locomotive, it is recommended to use 24V supply rather than unstable V, to ensure reliable and stable operation of the unit. When the voltage is extremely unstable, the measured or recorded data may be incorrect.

2. If this unit uses AC power, it can work within the

20%/50Hz range. However, when the AC power supply is extremely unstable, for example, powered by a self-owned generator, it must be ensured that the power supply parameters are within the above range; otherwise, the measured or recorded data may be incorrect.

3. The magnet supplied with this unit has

extremely strong magnetism; do not place it arbitrarily. The magnet should be kept away from magnetic cards, watches, mobile phones, and other items to avoid damaging these items. 4. Although this instrument has adopted certain protective measures, care should still be taken to place the main unit in an environment free from rain and snow and strong direct sunlight. In locations with heavy dust and oil contamination, sockets on the rear panel of the main unit, whether in use or temporarily unused, should be covered with protective covers or tape, which can greatly reduce the failure rate of the instrument.

5. Do not forcibly insert or pull out plugs. Power cables and data

cables must not be pulled forcefully, and must be protected from heavy objects and sharp tools. 6. When cleaning the main unit, setter, and sensor housing, a damp cloth can be used. For more heavily soiled areas, a cloth dipped in a small amount of low-concentration alcohol can be used for gentle wiping, or a dedicated computer housing cleaner can be used. It is strictly forbidden to use solvents such as gasoline, and strictly forbidden to clean by soaking or spraying water. 7. If the unit is not used for a long time, cut off the power, and store the unit and its accessories in the instrument case, keeping it clean and dry.

When the data cable is coiled for storage, it should be wound on the cable reel, and both plugs should be wrapped with protective tape to prevent moisture and dust ingress. Note : Due to technological progress, changes in appearance, principles, and technical parameters are subject to change without notice.

VII. Common Faults and Troubleshooting Methods

Note:

If you still cannot solve the problem according to the above methods or encounter other faults, please call the company's after-sales service department so that professional personnel can be assigned to solve it.

Appendix 1:

Representation of the local well number This instrument can set the well number through the setter. The well number is used to indicate features such as the working location of the instrument, so as to correctly analyze the printed data information. The well number is divided into three groups. The first group (code a ) is two digits, and the second group (code and the third group (code are three digits. Code a corresponds to Chinese characters; the meanings of code and code are determined by the user. While printing the measurement data, the local well number can also be printed. The well number consists of code a,

code and code ; among them, code is usually the corresponding Chinese character printed automatically. The Chinese characters currently designed for code a

corresponding to this instrument are:

Xi, Dong, Shan, Huang, Yan, Liu, Pan, Ning, Luo, Yu, Sai, Geng, Zhen, Ping, Hou, Xing, Wang, Ling, Bai, Xin, Hu, Yuan, Yang (a total of 23 Chinese characters) For example, when code a is set to code is set to and code is set to the printed well number result is Huang _015_302 Note: If code 24

is set, the printed result is:

When the code set on this unit is equal to or greater than 24, the Chinese character position recorded and printed corresponds to the set code.

Appendix 2:

Chinese character table corresponding to well number code a

No.Fault phenomenonFault causeRemedy
1Main unit indicators and digital display do not lightPower not connected properlyCheck the power cable and plug/socket, and reconnect the power
2When the traveling pulley is running, sensor A and B indicators do not light or only one lights (the frequency of indicator lighting depends on the traveling pulley rotation speed)Poor contact of sensor plug/socket or poor cable connectionCheck the plug/socket and ensure reliable connection
Cable broken or damagedConnect the broken cable or replace the cable
Magnet damagedReplace the magnet
Sensor bracket loose or tiltedReinstall and fix the sensor
Sensor damagedReplace the sensor
3Data displays "F" or recorded data error is very largePower supply extremely unstable or power supply voltage too lowUse the specified power supply
"Clear" key operated accidentallyDo not press "Clear" while the swab is below the wellhead
4Depth data error is relatively largePulley circumference setting inaccurateMeasure the circumference accurately and reset the circumference data (effective after restart)
5Printer does not work properlyPoor power startupReconnect the printer power
Printed data unclearReplace the printer ribbon
6Displayed time inaccurateAccumulated error after long-term use or time setting incorrectReset the time with the setter
Code aChinese characterCode aChinese characterCode aChinese characterCode aChinese characterCode aChinese character
01Bai06Huang11Pan16Xi21Yu
02Dong07Ling12Ping17Xin22Yuan
03Geng08Liu13Sai18Xing23Zhen
04Hou09Luo14Shan19YanAfter 24Same as code
05Hu10Ning15Wang20Yang